• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Medicine
  • Medicine Research
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Medicine
  • Medicine Research
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Solely abluminal drug release from coronary stents could possibly improve reendothelialization

    Thumbnail
    Date
    2016
    Author
    Zhang, Haijun
    Deng, Wei
    Wang, Xiangfei
    Wang, Shenguo
    Ge, Junbo
    Toft, Egon
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    Objectives To compare a new stent with an asymmetric coating, eluting the drug to the abluminal surface, to a stent with a conventional coating eluting the drug both to the luminal and the abluminal side. Background Stents with asymmetric coating, eluting the drug to the vessel wall (BPSES-A), could potentially give faster reendothelialization after percutaneous coronary interventions (PCI) and decrease in in-stent thrombosis and late restenosis. Methods BPSES-A, conventional coated stents (BPSES-C), biodegradable polymer stents without drug (BPS, for control), and bare metal stents (BMS, for control) were implanted into the coronary arteries of 38 pigs (75 stents). Pigs were sacrificed after 4, 12, and 24 weeks. Quantitative coronary angiography was used to compare in-stent late lumen loss (LLL) and electron microscopy was used to reveal levels of reendothelialization. Results The stents were all successfully implanted. LLL of BPSES-A, BPSES-C, BMS, and BPS were 0.56 ± 0.51, 0.60 ± 0.58, 0.89 ± 0.43, and 1.68 ± 0.30 mm, respectively, after 4 weeks. LLL of BPSES-A and BPSES-C were 0.63 ± 0.53 and 0.69 ± 0.24 mm, respectively, after 12 weeks. LLL of BPSES-A, BPSES-C, and BMS were 0.42 ± 0.15 m, 0.56 ± 0.28 mm, and 0.99 ± 0.13 mm, respectively, after 24 weeks. The scaling of reendothelialization was as follows: after 4 weeks BMS > = BPS > BPSES-A > BPSES-C, after 12 weeks BPSES-A > BPSES-C, and after 24 weeks BMS > BPSES-A > BPSES-C. Reendothelialization was better in BPSES-A than BPSES-C (P < 0.05). There was no correlation between LLL and reendothelialization (P = 0.42).
    DOI/handle
    http://dx.doi.org/10.1002/ccd.25335
    http://hdl.handle.net/10576/21170
    Collections
    • Medicine Research [‎1794‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video