Postfault control of scalar (V/f) controlled asymmetrical six-phase induction machines
(
Institute of Electrical and Electronics Engineers Inc.
, 2018 , Article)
With the accelerated development in semiconductor power devices along with the dictated rigorous reliability standards in some industrial sectors, the application of a medium-voltage high-power multiphase induction machine ...
Assessment of sensorless Kalman filter-based dual-loop control strategies for grid-connected VSIs with LCL filters
(
Institute of Electrical and Electronics Engineers Inc.
, 2015 , Conference Paper)
This paper illustrates the assessment between the multiloop control strategies that aim to damp the resonance hazard of LCL-filters and expanding the available stability margins. The establishment of the multiloop control ...
Discrete time domain analysis and optimal design of stationary frame AC current controllers with active damped LCL Filter for high power applications
(
IEEE Computer Society
, 2014 , Conference Paper)
Due to the large variety of renewable power sources, power electronics play an important role in energy conversion. Different power converter topologies are used to interface distributed power generation systems (DPGS) ...
A grid-connected HVDC shunt tap based on series-input parallel-output DC-AC multi-module 2-level voltage source converters
(
Institute of Electrical and Electronics Engineers Inc.
, 2015 , Conference Paper)
Tapping-off a small amount of power from an HVDC transmission line to a three-phase local grid can be achieved by using shunt or series HVDC taps. This paper proposes a new grid-connected HVDC shunt tap. The proposed tap ...
Sensorless V/f control with MRAS speed estimator for a five-phase induction machine under open-circuit phase faults
(
IEEE
, 2013 , Conference Paper)
This paper introduces a sensorless scalar controller with MRAS speed estimator based on simple Proportional Resonant PR controllers to provide a disturbance-free operation to a five-phase induction machine under phase open ...
Sensorless field oriented control of five-phase induction machine under open-circuit phase faults
(
IEEE
, 2013 , Conference Paper)
Recently, multiphase machine is promoted to replace three-phase drives in high power safety-critical applications. Among the numerous advantages of multiphase induction machine drives, operation and self-starting under ...
Non-linear sliding-mode control of three-phase buck-boost inverter
(
Institute of Electrical and Electronics Engineers Inc.
, 2014 , Conference Paper)
The development of static power converters capable of transforming DC energy obtained from alternative sources into AC has become one of the main challenges in renewable energy systems. In this context, the buck-boost ...
Performance assessment of single and dual loops discrete PR controllers with LCL filter for inverter-based distributed generation
(
IEEE Computer Society
, 2014 , Conference Paper)
Due to the rapid growth of the electric energy demands, the necessity of involvement of distributed generation (DG) to overcome this demand became a must. When distributed generation renewable energy sources are coupled ...
Investigation of inter-line dynamic voltage restorer with virtual impedance injection
(
IEEE
, 2010 , Conference Paper)
The Inter-Line Dynamic Voltage Restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for voltage sag ...
Vector control of multiphase induction machine under open-circuit phase faults
(
IEEE Computer SocietyIEEE
, 2013 , Conference Paper)
Multiphase induction machine is normally controlled using rotor field oriented vector control. Under phase(s) loss, the machine currents can be optimally controlled to satisfy certain optimization criteria. In this paper, ...