Assessment of sensorless Kalman filter-based dual-loop control strategies for grid-connected VSIs with LCL filters
الملخص
This paper illustrates the assessment between the multiloop control strategies that aim to damp the resonance hazard of LCL-filters and expanding the available stability margins. The establishment of the multiloop control is sustained in a sensorless manner with the reconstruction of the state variables using the Kalman observer, thus enhancing the cost measures and reliability of the distributed generation (DG) interface. Compared to the conventional multiloop techniques, which is mainly based on the feedback of either the filter capacitor current or voltage, the proposed multiloop method is able to exhibit: 1) theoretical stability through the whole frequency spectrum; 2) higher disturbance rejection originating from the grid-side interference; 3) higher damping of the dominant poles with much lower control effort than the conventional methods; 4) straightforward tuning of the grid current controller as the LCL-filter appears as an apparent standard second order model; and 5) low sensitivity against parameter deviations compared to previous literatures. Furthermore, the utilized control scheme ensures a high quality of injected grid currents under unbalanced and distorted grid voltage conditions. Experimental results validated the proposed control concept through a 3.5 kW setup.
المجموعات
- الهندسة الكهربائية [2649 items ]
وثائق ذات صلة
عرض الوثائق المتصلة بواسطة: العنوان، المؤلف، المنشئ والموضوع.
-
A stationary frame current control for inverter-based distributed generation with sensorless active damped LCL filter using Kalman filter
El-Deeb, H.M.; Elserougi, A.; Abdel-Khalik, A.S.; Ahmed, S.; Massoud, Ahmed ( Institute of Electrical and Electronics Engineers Inc. , 2014 , Conference Paper)Due to the large variety of renewable power sources, power electronics play an important role in energy conversion. Different power converter topologies are used to interface distributed power generation systems (DPGS) ... -
Multiloop control strategy for grid-interfaced three-phase voltage source inverter with passively damped LLCL-filter
Azani, H.; Massoud, Ahmed; Ben-Brahim, L.; Williams, B.W.; Holliday, D. ( Institution of Engineering and Technology , 2014 , Conference Paper)In inverter-based distributed generation (IBDG) and similar to the conventional third order LCL filter, the high order LLCL filter is difficult to stabilize, and may cause a resonance between the inverter and the grid. ... -
Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters