A new modulation technique for wide-range control of output voltage in Z-source inverters
الملخص
Z-source inverter (ZSI) is recently proposed as a single-stage power conversion topology. It adds voltage boost capability for complementing the usual voltage buck operation of the traditional voltage source inverter with enhanced reliability. However, its boosting capability could be limited, and therefore, it may not be suitable for some applications requiring very high voltage boost. To enhance the boosting capability, this paper proposes a new modulation technique to control the generation of the shoot-through intervals in the Z-source inverters. The proposed modulation technique achieves reliable high voltage gain operation without adding any extra hardware to the ZSI structure which preserves its single stage nature. The proposed modulation technique is analyzed in details and its performance is validated using both simulation and experimentations.
المجموعات
- الهندسة الكهربائية [2649 items ]
وثائق ذات صلة
عرض الوثائق المتصلة بواسطة: العنوان، المؤلف، المنشئ والموضوع.
-
Investigation of inter-line dynamic voltage restorer with virtual impedance injection
Elserougi, A.; Hossam-Eldin, A.; Massoud, Ahmed; Ahmed, S. ( IEEE , 2010 , Conference Paper)The Inter-Line Dynamic Voltage Restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for voltage sag ... -
A Pulsewidth Modulation Technique for High-Voltage Gain Operation of Three-Phase Z-Source Inverters
Diab, Mohamed S.; Elserougi, Ahmed A.; Massoud, Ahmed M.; Abdel-Khalik, Ayman S.; Ahmed, Shehab ( Institute of Electrical and Electronics Engineers Inc. , 2016 , Article)Z-source inverter (ZSI) was recently proposed as a single-stage buck-boost dc-ac power conversion topology. It augments voltage boost capability to the typical voltage buck operation of the conventional voltage source ... -
A modified capacitor voltage control algorithm for suppressing the effect of measurement noise on grid-connected Z-source inverters controllers
Hakeem, A.A.; Elserougi, A.; El Zawawi, A.; Ahmed, S.; Massoud, Ahmed ( http://dx.doi.org/10.1109/IECON.2013.6699136 , 2013 , Conference Paper)Inverters are considered the orbit of research objectives for safe and reliable grid interface. Amongst the conventional inverters known as suitable candidates for gird connection in the last two decades, Z-source inverter ...