• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Fully Functional Secure Ubiquitous Healthcare Monitoring System

    Thumbnail
    View/Open
    qfarc.2014.HBPP1030.pdf (101.1Kb)
    Date
    2014
    Author
    Mehmood, Waiser
    Hassan, Ammad
    Touati, Farid
    Erdene-ochir, Ochirkhand
    Ben Mnaouer, Adel
    Gaabab, Brahim
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    BACKGROUND & OBJECTIVES Recent advances in sensing, communication and actuation are leading to the next generation of Telemedicine when integrated with Wireless Body Area Networks (WBANs). They have a great potential in fostering the provision of next-generation Ubiquitous Healthcare (U-Health). However, deploying new technologies in healthcare applications without considering security makes patient privacy vulnerable, especially when we deal with highly sensitive physiological data of a patient such as heart-rate, position, temperature etc. Because traditional security mechanisms have been designed for the systems with sufficient resources, they cannot be applied directly to the extremely resource constrained WBANs devices. Our main objective is to provide a lightweight security mechanism suitable for WBANs and propose a fully functional secure healthcare platform to monitor remotely the patients' health status. II. METHODS The proposed healthcare system (Fig. 1) integrates heterogeneous devices and wearable medical sensors. It informs the healthcare professionals by sending Patient Health Information (PHI) from Body Sensors to Body Router (BR). BR uses wireless local area network to communicate with Gateway in indoor environment, and it communicates with Server through 3G/4G in outdoor environment. Gateway and Server request Hardware Address Resolution Process (HARP) for security. To guarantee the system security, we propose (i) a new lightweight encryption scheme based on stream cipher, where the encryption key is changed after each round of transmission to provide strong confidentiality (ii) an authentication mechanism is provided through HARP to authenticate BRs with their unique ID assigned before deployment and to guarantee that only authorized healthcare professionals can access to patients' data thanks to their biometrical information. III. RESULTS In order to investigate the feasibility of the proposed secure healthcare system, all components have been implemented in an experimental testbed. Zolertia is used as a wearable BS, which is a MSP430 microcontroller based sensor node equipped with CC2420 RF transceiver for wireless communication. Cubox is used as a BR, which is a low power ARM architecture. PCs are used as Gateway/Server and HARP. Firstly, the security tests of the encryption scheme have been provided to check the randomness quality. The results were significantly higher (from 0.342178 to 0.974321) than the indicated threshold value (0.01) recommended by National Institute of Standards and Technology (NIST). Secondly, the end-to-end delay was around 97ms with encryption scheme and 94ms without encryption. Thus, the communication overhead incurred due to the encryption algorithm for each round is nearly 3ms. IV. CONCLUSION Experimental results have shown that our U-Health solution is feasible in real-world scenarios. The proposed encryption scheme passed all randomness tests recommended by NIST and the security functionality brings only 3ms communication overhead in terms of end-to-end delay per transmission.
    URI
    https://doi.org/10.5339/qfarc.2014.HBPP1030
    DOI/handle
    http://hdl.handle.net/10576/29653
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video