• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Arts & Sciences
  • Biological & Environmental Sciences
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Arts & Sciences
  • Biological & Environmental Sciences
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparison between nucleic acid amplification tests, antigen immunofluorescence assay, and in vitro infectivity in SARS-CoV-2 diagnosis.

    View/Open
    SARS-CoV2 diagnosis (641.7Kb)
    Date
    2022-04-21
    Author
    Zupin, Luisa
    Fontana, Francesco
    Clemente, Libera
    Ruscio, Maurizio
    Crovella, Sergio
    Metadata
    Show full item record
    Abstract
    The number of SARS-CoV-2 detection tests requested to the laboratories has dramatically increased together with an urgent need to release reliable responses in a very short time. The two options taken into consideration and analyzed in the current study were the point-of-care test (POCT) based on the nucleic acid amplification test (NAAT) and the Antigen (Ag) rapid test. The POCT-NAAT-based assay was compared with a rapid antigen test of nasopharyngeal swab samples. If the specimen tested positive, it was followed by viral load quantification and by the functional assessment of the residual infectivity. When the initial cycle threshold (Ct) was below 20 (100%), and in the range of 20-25 (92%) and of 25-30 (88%), a great concordance between the POCT-NAAT and the Ag test was observed. Moreover, the positivity of the antigen test was well correlated to a successful infection in vitro (78%), with greater concordance when the initial Ct below 20 or above 35 (100%) and in the range 20-25 (83%). Our findings showed that most of the swabs which tested positive using the antigen test were able to infect the cells in vitro, suggesting that probably only these samples hold residual infectivity and therefore an increased risk of virus transmission at the moment of being tested.
    DOI/handle
    http://dx.doi.org/10.1007/s42770-022-00758-6
    http://hdl.handle.net/10576/30432
    Collections
    • Biological & Environmental Sciences [‎931‎ items ]
    • COVID-19 Research [‎848‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video