• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Voltage Independent Reactive Current Based Sensor for Static VAr Control Applications

    Thumbnail
    Date
    2023
    Author
    Ikram, Mohd Kamran
    Amrr, Syed Muhammad
    Asghar, M. S. Jamil
    Islam, Tarikul
    Iqbal, Atif
    Metadata
    Show full item record
    Abstract
    The use of renewable energy-based converters is continuously increasing in modern power systems which inject voltage harmonics in the line. In this work, a novel, simple technique based on a binary (on/off) control of an analog switch is proposed to measure reactive current and reactive power. This method eliminates the requirement of finding sin( $\phi $ ) and its multiplication with the current signal in reactive power computation. The proposed transducer gives a dc signal proportional to the reactive current of a power system, i.e., ${I}$ sin( $\phi $ ), which is suitable for static VAr compensator (SVC) applications. This transducer output is sufficient as the terminal voltage is common for the measurement as well as for the compensation current. Thus, the required current of SVC for compensation is equal to or proportional to ${I}$ sin( $\phi $ ). Moreover, voltage harmonics are common in a power system. These harmonics affect the measurement of fundamental reactive power. This method eliminates the need for voltage measurement and hence the measurement is independent of the harmonics of the voltage, which reduces the measurement error. The proposed method is proved mathematically, and its performance is successfully validated through simulation analysis and hardware implementation. The advantages of the proposed technique are linearity of the transducer output, simple working, inexpensive hardware realization, fast response, and online measurement capability. The response time of the transducer is one cycle of supply voltage which is suitable for SVC applications. 2001-2012 IEEE.
    DOI/handle
    http://dx.doi.org/10.1109/JSEN.2023.3258696
    http://hdl.handle.net/10576/43062
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video