• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Bond durability and service life prediction of BFRP bars to steel FRC under aggressive environmental conditions

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S0263822321004943-main.pdf (4.583Mb)
    Date
    2021
    Author
    Taha, Alaa
    Alnahhal, Wael
    Metadata
    Show full item record
    Abstract
    This study presents an experimental investigation on the bond durability of helically wrapped basalt fiber reinforced polymer (BFRP) bars embedded in plain and steel fiber reinforced concrete (SFRC) under the combined effect of simulated oceanic environment and elevated temperatures. A total of sixty-three pullout specimens were tested to study the effect of concrete type (plain and SFRC), immersion temperature (35 °C and 60 °C), immersion duration (30, 60, and 90 days), and fiber volume fraction (Vf) of steel fibers (0.5% and 1%). The bond durability of the used bars was examined based on the bond strength and mode of failure. The BFRP bars at the interface along the embedment length with concrete were analyzed using scanning electron microscopy. In addition, the BPE and CMR models for bond-slip behavior were calibrated considering the immersion temperature, concrete type, and exposure duration. The experimental results revealed that the pullout specimens with Vf = 1% showed higher bond durability performance than specimens with Vf = 0.5%, particularly at high temperatures. Furthermore, the CMR model showed better correlation with the experimental data than the BPE model. Moreover, the 50 years service life prediction showed bond strength retentions of BFRP bars that ranged from 54% to 86% depending on the type of concrete (plain and SFRC), surrounding mean annual temperature (5 °C to 35 °C), and degree of moisture (dry, moist, and moisture saturated).
    DOI/handle
    http://dx.doi.org/10.1016/j.compstruct.2021.114034
    http://hdl.handle.net/10576/50250
    Collections
    • Civil and Environmental Engineering [‎862‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video