• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    The Influence of Reinforcement Ratio on the Shear Behaviour of Sand Coated Basalt FRP Bars Reinforced Beams

    Thumbnail
    Date
    2022
    Author
    Al-Hamrani, Abathar
    Alnahhal, Wael
    Metadata
    Show full item record
    Abstract
    Qatar is known by its harsh corrosive environment that is represented by high periodical humidity, and dust accompanied by temperature fluctuation. Also, geographically Qatar is considered a peninsula, this in turn makes it highly susceptible to seawater spray which contains high chloride contents. Recently, basalt fiber reinforced polymer (BFRP) bars are among the most investigated types of anti-corrosive advanced composites in structures. Accordingly, the present paper aims at examining the efficiency of sand coated basalt fiber reinforced polymer (SBFRP) bars and ribbed glass (GFRP) stirrups in resisting shear stresses in large scale basalt fiber reinforced concrete (BFRC) beams. The effect of the reinforcement ratio ρf (2.054 ρfb and 4.53 ρfb where ρfb is the balanced reinforcement ratio) on the shear capacity of the tested beams was investigated. Results revealed an increase in the ultimate load capacity by 48% when the reinforcement ratio was increased from 2.054 ρfb to 4.53 ρfb. Also, it was clearly noticed that the beam stiffness has significantly enhanced at higher reinforcement ratio, especially after the onset of first flexural crack.
    DOI/handle
    http://dx.doi.org/10.1007/978-3-030-88166-5_85
    http://hdl.handle.net/10576/57495
    Collections
    • Civil and Environmental Engineering [‎869‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video