Failure analysis of 316L air cooler stainless steel tube in a natural gas production field
المؤلف | Radwan, A. Bahgat |
المؤلف | Abdullah, Aboubakr M. |
المؤلف | Roven, Hans J. |
المؤلف | Mohamed, Adel M. |
المؤلف | Mobbassar Hassan, SK |
تاريخ الإتاحة | 2024-09-16T10:35:12Z |
تاريخ النشر | 2015 |
اسم المنشور | International Journal of Electrochemical Science |
المصدر | Scopus |
الرقم المعياري الدولي للكتاب | 14523981 |
الملخص | In spite of the excellent resistance of stainless steel (SS) towards uniform corrosion, overcoming various localized corrosion could be a real challenge. This work presents an analysis of the failure behavior of 316L SS air chiller tube with a peripheral crack used in a Qatari gas company in Qatar. Macroscopic failure characteristics were analyzed by means of visual inspection, digital imaging while light microscopy, electron microscopy (SEM / EDX), and X-ray fluorescence (XRF) were employed for microstructural and fractographic characterization. The results indicate that the failure phenomenon that was primarily initiated by Cl- led to an eventual autocatalytic pitting corrosion. The failure reasons of the tube are related to the combined effect of constant and cyclic external stresses, as well as internal residual stress originated from various operating conditions. |
راعي المشروع | ACKNOWLEDGMENTS The authors would like to express their grateful acknowledgment for financial and received from the Centre for Advanced Materials, (CAM), Qatar University. |
اللغة | en |
الناشر | Elsevier |
الموضوع | Failure analysis Fractography Inclusions Pitting corrosion Stainless steel |
النوع | Article |
الصفحات | 7606-7621 |
رقم العدد | 9 |
رقم المجلد | 10 |
تحقق من خيارات الوصول
الملفات في هذه التسجيلة
هذه التسجيلة تظهر في المجموعات التالية
-
الأبحاث [1378 items ]