Show simple item record

AuthorMuchharla, Baleeswaraiah
AuthorBarbee, Brianna
AuthorDarby, Marlon
AuthorCao, Wei
AuthorElsayed–Ali, Hani
AuthorSadasivuni, Kishor Kumar
AuthorAdedeji, Adetayo
AuthorKumar, Kapil
AuthorKaroui, Abdennaceur
AuthorPanwar, Preety
AuthorSlaughter, Gymama
AuthorKumar, Bijandra
Available date2025-01-30T09:28:11Z
Publication Date2023-06-01
Publication NameMaterials Today Communications
Identifierhttp://dx.doi.org/10.1016/j.mtcomm.2023.106286
CitationMuchharla, B., Barbee, B., Darby, M., Cao, W., Elsayed–Ali, H., Sadasivuni, K. K., ... & Kumar, B. (2023). Oxide derived Cu nanofibril assembly for enhanced nonenzymatic glucose sensing. Materials Today Communications, 35, 106286.‏
URIhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85160201670&origin=inward
URIhttp://hdl.handle.net/10576/62667
AbstractIn this report, we have prepared copper nanofibril assembly via thermal oxidation followed by electrochemical reduction processes, exhibiting superior glucose detection ability. The morphological analysis evidenced the formation of rough islands or nanofibril structure on the Cu surface depending on initial thermal oxidation temperature. The glucose detection performance was investigated by performing cyclic voltammetry and chronoamperometry with varying glucose concentration. A high sensitivity (4131.57 μA mM−1 cm−2), low detection limit (1.41 μM), wider linear range (0–3.9 mM) and long–term stability (30 days) have been recorded for electrode thermally oxidized at 400 °C followed by electrochemical reduction process (rCu_400). The sensitivity is almost three times higher in comparison to the planner Cu surface. This significantly enhanced glucose sensing ability rCu_400 has been attributed to the nanofibril morphology, origination of Cu (111) facet and formation of a stable oxide layer evidenced by scanning electron microscopy, X-ray diffraction and energy dispersive spectroscopy analysis. Despite higher sensitivity, rCu_400 electrode does not show any response to the chloride ion, dopamine, ascorbic acid and uric acid. These results indicate that the Cu nanofibril structure prepared via simple oxidation/reduction process can be an excellent candidate to be used as an electrode for glucose sensing application.
Languageen
PublisherElsevier Ltd
SubjectCopper nanofibril structure
Glucose detection
Nanocatalysts
Nonenzymatic sensor
TitleOxide derived Cu nanofibril assembly for enhanced nonenzymatic glucose sensing
TypeArticle
Volume Number35
dc.accessType Open Access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record