    A Validated Reverse-Phase High Performance Liquid Chromatography (RP-HPLC) Method for the Quantification of Gamma-Tocotrienol in Tocotrienol Rich Fractions of Crude Palm Oil

    Thumbnail
    Date
    2021-08-03
    Author
    Nair, Rajesh Sreedharan
    Billa, Nashiru
    Morris, Andrew
    Metadata
    Show full item record
    Abstract
    Background: Palm oil and its constituents have wide applications in food, cosmet-ics and pharmaceutical industries. The tocotrienol-rich fractions of crude palm oil have drawn greater research interest in recent years due to their potent health benefits. Therefore, reliable and validated analytical methods are essential for the quantification of tocotrienols. Objective: This study aimed to develop a simple and economical RP-HPLC method for the quantification of gamma-tocotrienol in tocotrienol-rich fractions of crude palm oil. Methods: An Agilent HPLC system supplied with a Diode Array detector and an auto-injector system was used for the method development, and the wavelength was set 295 nm. A reversed-phase C18 column maintained at 30 °C using a mobile phase composition of methanol: water (95:05) at a flow rate of 1 mL/min was used for the analysis. The developed method was validated according to ICH guidelines. Results and Discussion: A symmetrical peak of gamma-tocotrienol was observed at 8.7 minutes with minimal peak tailing (between 0.76 and 0.78), and an acceptable resolution above 2.0. Excellent linearity was evident with R2 values 0.9996 and 0.9991 for intra-day and inter-day, respectively. The method demonstrated a high precision (%RSD values ≤ 5.8%) and accu-racy (%RE<9.6%). The LOD and LOQ of gamma-tocotrienol were determined as 1.4 μg/mL and 4.2 μg/mL, respectively. The system suitability studies indicate that the chromatographic parameters are well within the acceptable limit. Conclusion: In conclusion, the developed RP-HPLC method is rapid, precise, stable and economical for the quantification of gamma-tocotrienol.
    URI
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85125704223&origin=inward
    DOI/handle
    http://dx.doi.org/10.2174/1573401317666210803155717
    http://hdl.handle.net/10576/41423
    Collections
    • Pharmacy Research [‎1389‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video