Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods.
المؤلف | K Nasrallah, Gheyath |
المؤلف | Younes, Nadin |
المؤلف | Khalid, Hadiya M |
المؤلف | Al-Emadi, Jawaher A |
المؤلف | Younes, Salma |
المؤلف | Abouassali, Mazen Najib |
المؤلف | Elshaikh, Manal Abdelmutaal |
المؤلف | Karime, Ibrahim Wisam |
المؤلف | Ibrahim, Mohammed Abdelfatah |
المؤلف | Ali, Mutaz Mohamed |
المؤلف | Shaar, Ibrahim Al |
المؤلف | Liu, Na |
المؤلف | Ayoub, Houssein |
المؤلف | Yassine, Hadi M |
المؤلف | Abu-Raddad, Laith J |
المؤلف | Ismail, Ahmed |
تاريخ الإتاحة | 2024-11-20T10:03:46Z |
تاريخ النشر | 2024-11-15 |
اسم المنشور | scientific reports |
المعرّف | http://dx.doi.org/10.1038/s41598-024-78271-z |
الاقتباس | K. Nasrallah, G., Younes, N., Khalid, H.M. et al. Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods. Sci Rep 14, 28177 (2024). https://doi.org/10.1038/s41598-024-78271-z |
الملخص | Architect-HIV Ag/Ab combo chemiluminescence assay is globally recognized for its sensitivity but has a notable false-positive rate. In this study, we aim to evaluate the performance of a new cost-effective screening alternative, the chemiluminescence Ag/Ab combo assay (CL-900i-HIV) from Mindray, China. We selected 195 archived samples categorized according to the INNO-LIA™ HIV I/II, the gold standard confirmatory assay. These samples included true positive (n = 38; positive by Architect-HIV & INNO-LIA-HIV), true negative (n = 101; negative by Architect-HIV & INNO-LIA-HIV), false positive (n = 20; positive by Architect-HIV & negative by INNO-LIA-HIV), and indeterminate results (n = 26). We tested all samples using the Mindray CL-900i-HIV and all positive Architect-HIV samples (n = 80) were confirmed by PCR. Compared to INNO-LIA™ HIVI/II line immunoassay confirmatory assay, Mindray CL-900i-HIV demonstrated a sensitivity of 100% (95% CI 90.7-100), specificity of 100% (95% CI 97.0-100), overall percent agreement (OPA) of 100% (95% CI 97.7-100.0), and perfect agreement with the INNO-LIA confirmatory assay (κ = 1.00). Additionally, Mindray's CL-900i-HIV exhibited a significantly lower false-positive rate (8.75%) compared to Architect-HIV's (55%). Mindray CL900i demonstrated high sensitivity and very low false-positive rate, thus, has the potential to serve as an excellent, cost-effective surrogate for HIV screening, overcoming the limitations of existing automated assays. |
راعي المشروع | Gheyath Nasrallah would like to acknowledge receiving funds from NPRP13S-0128-200185 and UREP30-041-3-014 grants from Qatar National Research Fund (QNRF), a member of Qatar Foundation, as well as QUCG-CHS-23/24–170 from Qatar University. Houssein Ayoub, Laith Abu-Raddad and Gheyath Nasrallah would like to acknowledge receiving funds from Qatar University under grant QUCG-CAS-23/24–114. Nadin Younes would like to acknowledge receiving funds from GSRA8-L-1-0501-21022 from QNRF. It is important to note that the funders played no role in the study design, data collection, analysis, decision to publish, or preparation of the manuscript. All statements made in this report are solely the responsibility of the authors. |
اللغة | en |
الناشر | Springer Nature |
الموضوع | AIDS CLIA Diagnosis HIV Infectious disease |
النوع | Article |
رقم العدد | 1 |
رقم المجلد | 14 |
ESSN | 2045-2322 |
الملفات في هذه التسجيلة
هذه التسجيلة تظهر في المجموعات التالية
-
أبحاث مركز البحوث الحيوية الطبية [740 items ]
-
العلوم الحيوية الطبية [739 items ]
-
الرياضيات والإحصاء والفيزياء [742 items ]