Unmasking hemoglobin Köln: a rare cause of discrepancies between pulse oximetry and arterial oxygen saturation—a case report
المؤلف | Alshurafa, Awni |
المؤلف | Elsabagh, Ahmed |
المؤلف | Obaid, Koutaibah Rida |
المؤلف | Elhaji, Youssef |
المؤلف | Yassin, Mohamed A. |
تاريخ الإتاحة | 2024-12-15T09:05:00Z |
تاريخ النشر | 2024-01-01 |
اسم المنشور | Frontiers in Medicine |
المعرّف | http://dx.doi.org/10.3389/fmed.2024.1368068 |
الاقتباس | Alshurafa, A., Elsabagh, A., Obaid, K. R., Elhaji, Y., & Yassin, M. A. (2024). Unmasking hemoglobin Köln: a rare cause of discrepancies between pulse oximetry and arterial oxygen saturation—a case report. Frontiers in Medicine, 11, 1368068. |
الملخص | Discrepancies between pulse oximetry and arterial oxygen saturation can pose challenges in clinical assessment. Possible underlying causes include poor peripheral perfusion, skin pigmentation, motion artifacts, and conditions like unstable hemoglobin and methemoglobinemia. Unstable hemoglobin variants, such as hemoglobin Köln, are rare inherited mutations affecting globin genes, potentially disrupting the folding, assembly, or interactions among subunits in globin molecules and the essential interactions between heme and globin for oxygen-binding properties. In this case report, we present the case of a 44-year-old Arabic woman who underwent extensive investigations due to disparities in pulse oximetry and arterial oxygen saturation, ultimately leading to the diagnosis of the unstable hemoglobin variant, hemoglobin Köln. |
اللغة | en |
الناشر | Frontiers Media SA |
الموضوع | hemoglobin hemoglobinopathies hemolysis hypoxia unstable hemoglobin |
النوع | Article |
رقم المجلد | 11 |
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
أبحاث الطب [1537 items ]