• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Medicine
  • Medicine Research
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Medicine
  • Medicine Research
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    "Double-Lumen Valve-Controlled Intra-Operative Pyeloplasty Stent (VIPs)": A New Technology for Post-Pyeloplasty Stenting - Proof of Concept Study in a Preclinical Large Animal Model

    Thumbnail
    View/Open
    rru-238572-ldquo-double-lumen-valve-controlled-intra-operative-pyelopl.pdf (6.999Mb)
    Date
    2020
    Author
    Abbas, Tariq O.
    Ali, Mansour
    Moog, Raphael
    Metadata
    Show full item record
    Abstract
    Background: Pyeloplasty is a common surgical operation with a high success rate. However, significant challenges are to be optimized in the design of stenting systems in order to improve perioperative monitoring of urine drainage and enhance patient and family comfort through easier post-operative care. Materials and Methods: In a preliminary study in six pigs, handling, mechanical and functional features of this stent system were tested. In our main study, six double-lumen stents (230 mm long each) and 6F/9F external diameter were implanted through the ureteric walls of six domestic pigs to allow postoperative drainage and monitoring following ureter-oureterostomy. After a 7-day survival period, monitoring with intravenous antibiotic coverage, and pain control, contrast antegrade pyelogram, under valve control, and renal ultrasonography were conducted and stents explanted and the animals were then euthanized. Results: The double-lumen valve-controlled stent supported the healing of the neo anasto-moses and helped to monitor perioperative urine drainage and perianastomotic leakage accurately. It also guided a well-controlled more informative radiological contrast-supported imaging before removal of the stents that confirmed the healing of the neo anastomotic site and no leak formation. The double-lumen system demonstrated high feasibility regarding its insertion, functionality, and removal capacities. The excellent flexibility of the individual stents allowed exact anatomically controlled implantation. Conclusion: The double-lumen valve-controlled stent system was studied in a porcine model, which demonstrated its feasibility. Preclinical experience revealed favorable results concerning stent implantation, operability and functionality, in the perioperative management of pyeloplasty or ureteric surgery.
    DOI/handle
    http://dx.doi.org/10.2147/RRU.S238572
    http://hdl.handle.net/10576/63814
    Collections
    • Medicine Research [‎1739‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video