عرض بسيط للتسجيلة

المؤلفChandrasekharam, Vvs
المؤلفAbbas, Tariq O.
المؤلفBabu, Ramesh
تاريخ الإتاحة2025-10-14T07:46:11Z
تاريخ النشر2025-05-08
اسم المنشورJournal of Pediatric Urology
المعرّفhttp://dx.doi.org/10.1016/j.jpurol.2025.05.004
الاقتباسBabu, R., Chandrasekharam, V., & Abbas, T. O. (2025). Objective assessment of penile curvature in hypospadias: A narrative review. Journal of Pediatric Urology.
الرقم المعياري الدولي للكتاب1477-5131
معرّف المصادر الموحدhttps://www.sciencedirect.com/science/article/pii/S1477513125002736
معرّف المصادر الموحدhttp://hdl.handle.net/10576/67908
الملخصBackgroundHypospadias-associated ventral curvature (VC) exerts a critical influence on surgical decision-making and repair outcomes. Despite the clinical significance of VC, assessment is frequently performed by unaided visual inspection (UVI) which is prone to error. Alternative objective measurement techniques have therefore been proposed, including goniometry, smartphone applications, and artificial intelligence (AI)-based tools. ObjectiveThis review aims to evaluate the various techniques available for VC measurement in hypospadias surgery, focusing on their accuracy, reliability, and clinical utility. MethodsA comprehensive literature search was conducted using PubMed, MEDLINE, and the Cochrane Database, covering publications from 1994 to 2024. Included studies assessed VC measurement techniques, including UVI, standard goniometry, smartphone-based goniometry, and AI-based tools. Risk of bias was determined using the Robvis tool. ResultsOf 501 studies identified, 13 met the inclusion criteria. Findings revealed that UVI was associated with significant inaccuracy, leading to misclassification of VC severity and potential errors in surgical planning. Standard goniometry, while objective, was cumbersome in pediatric patients due to parallax errors and anatomical constraints. Smartphone-based goniometry provided improved accuracy and interobserver reliability. AI-based methods demonstrated the highest precision by minimizing subjectivity and enhancing standardization. ConclusionObjective measurement techniques, particularly smartphone-based and AI-driven approaches, are superior to UVI in assessing penile curvature in hypospadias. Future advances in AI technology and digital imaging may further refine VC assessment, leading to improved surgical outcomes. Adoption of standardized, objective measurement methods should be encouraged in clinical practice.
اللغةen
الناشرElsevier
الموضوعHypospadias
Ventral curvature
Goniometry
Smartphone application
Artificial intelligence
Surgical decision-making
العنوانObjective assessment of penile curvature in hypospadias: A narrative review
النوعArticle
رقم العدد4
رقم المجلد21
ESSN1873-4898
dc.accessType Full Text


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة