    Finite Element Analysis of Self Expanding Transcatheter Aortic Valves reveals Increased Stent contact Pressure is Associated with Higher Conduction Abnormality Risk

    Thumbnail
    View/Open
    2025-HCYalcin-HVBTE-TAVI.pdf (246.9Kb)
    Date
    2025-10-01
    Author
    Yalcin, Huseyin C.
    Mutlu, Onur
    Mazhar, Noaman
    Lajpat, Himanshu
    Al-Nabti, Abdulrahman
    Metadata
    Show full item record
    Abstract
    For transcatheter aortic valve implantation (TAVI), selecting optimal valve size and implantation depth within aortic root is crucial for preventing complications, such as conduction problems and paravalvular leak. Computational modeling offers comprehensive assessment of patient-specific TAVI scenarios at pre-operative stage enabling calculation of aortic wall mechanical stresses and deformations from the implanted valve. Here, our objective is to develop patient-specific finite element computational modeling approaches for comprehensive biomechanical assessment of TAVI to investigate correlations between post-TAVI aortic wall mechanics and post-TAVI complications. This investigation is in collaboration with Hamad Heart Hospital TAVI program in Qatar where Medtronic Core Valve is the most commonly used TAV, hence we focused on this valve type. A total of 54 retrospective cases were analyzed. Among the study cohort, 24 patients received 26mm valve, 23 patients received 29mm valve, and 7 patients received 34mm valve. ABAQUS finite element analysis (FEA) software was used for complete TAVI simulation operation. For each TAVI case, FEA revealed biomechanical stress and deformation patterns on aortic root. Studied parameters are average and maximum values of contact pressure, von mises stresses, and radial displacements. Studied cases were grouped into cases that experienced complications post-TAVI and cases that did not experience complications post-TAVI. Using ABAQUS, we successfully simulated complete TAVI implantation and carried out FEA for aortic root stress and deformation patterns for studied cases. Statistical analysis revealed that TAVI contact pressure was higher for cases suffering from conduction abnormalities, suggesting stent pressure is an important factor influencing conduction abnormalities experienced post-TAVI. FEA is a powerful approach for simulating TAVI and predicting possible post-TAVI complications, and advancing such models will enhance therapy planning for TAVI therapy.
    DOI/handle
    http://dx.doi.org/10.21542/gcsp.2025.hvbte.63
    http://hdl.handle.net/10576/68288
    Collections
    • Biomedical Research Center Research [‎840‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us
    Contact Us | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us
    Contact Us | QU

     

     

    Video