الاقتباسPrajapati, P., Patil, Y., Haque, A., Kalam, M. A., & Shah, S. (2025). Development and Characterization of Sensitive, Eco‐Friendly, and Selective Microwave‐Aided Fluorodensitometric Probe for Estimation of Alfuzosin Using Comprehensive Approach of Multicolored Analytical Chemistry and Design of Experiments. Luminescence, 40(12), e70372.
الرقم المعياري الدولي للكتاب1522-7235
معرّف المصادر الموحدhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105023452263&origin=inward
معرّف المصادر الموحدhttp://hdl.handle.net/10576/69472
الملخصExisting methods for AFZ estimation lacked sensitivity for picoscale detection in biological samples, faced matrix interferences, and used environmentally harmful solvents. A sensitive, selective, and eco-friendly microwave-assisted fluorodensitometric probe was developed for picoscale estimation of AFZ in pharmaceutical formulations and human plasma. The method utilized a microwave-assisted microlevel Hantzsch reaction for the generation of a fluorodensitometric probe for AFZ derivatization in the microenvironment of a silica plate. A design of experiments (DoE) approach was implemented using a Plackett–Burman design for risk assessment and a minimum run resolution IV design for response surface analysis. HPTLC–MS was used for the characterization of the fluorodensitometric probe generated by microwave-aided microlevel condensation of organic liquids and AFZ. The method demonstrated linearity in the range of 10–50 pg/band with high sensitivity (LOD: 3.0 pg/band, LOQ: 10.0 pg/band). Precision and accuracy were within acceptable limits. The method was successfully applied to pharmaceutical formulations and different plasma samples. The proposed method offers a sensitive, selective, and environmentally friendly approach for AFZ estimation at picoscale levels, adhering to white analytical chemistry principles and the QbD approach.
راعي المشروعThe director of Maliba Pharmacy College is obliged by the writers ofthis piece to supply the resources that allowed them to conduct theirresearch. Uka Tarsadia University's Provost and CEO, who provided thenecessary infrastructure and resources, also deserves gratitude fromthe writers of the manuscript. The authors extend their appreciation tothe Ongoing Research Funding Program (ORF-2025-726), King SaudUniversity, Riyadh, Saudi Arabia.
اللغةen
الناشرJohn Wiley and Sons Ltd
الموضوعalfuzosin
microenvironment
microwave-assisted fluorodensitometric probe
minimum run resolution IV design
quality by design approach
العنوانDevelopment and Characterization of Sensitive, Eco-Friendly, and Selective Microwave-Aided Fluorodensitometric Probe for Estimation of Alfuzosin Using Comprehensive Approach of Multicolored Analytical Chemistry and Design of Experiments
النوعArticle
رقم العدد12
رقم المجلد40
ESSN1522-7243
dc.accessType Full Text


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة