Development and Characterization of Sensitive, Eco-Friendly, and Selective Microwave-Aided Fluorodensitometric Probe for Estimation of Alfuzosin Using Comprehensive Approach of Multicolored Analytical Chemistry and Design of Experiments
| Author | Prajapati, Pintu |
| Author | Patil, Yash |
| Author | Haque, Anzarul |
| Author | Kalam, Mohd Abul |
| Author | Shah, Shailesh |
| Available date | 2026-01-22T09:01:11Z |
| Publication Date | 2025-12-01 |
| Publication Name | Luminescence |
| Identifier | http://dx.doi.org/10.1002/bio.70372 |
| Citation | Prajapati, P., Patil, Y., Haque, A., Kalam, M. A., & Shah, S. (2025). Development and Characterization of Sensitive, Eco‐Friendly, and Selective Microwave‐Aided Fluorodensitometric Probe for Estimation of Alfuzosin Using Comprehensive Approach of Multicolored Analytical Chemistry and Design of Experiments. Luminescence, 40(12), e70372. |
| ISSN | 1522-7235 |
| Abstract | Existing methods for AFZ estimation lacked sensitivity for picoscale detection in biological samples, faced matrix interferences, and used environmentally harmful solvents. A sensitive, selective, and eco-friendly microwave-assisted fluorodensitometric probe was developed for picoscale estimation of AFZ in pharmaceutical formulations and human plasma. The method utilized a microwave-assisted microlevel Hantzsch reaction for the generation of a fluorodensitometric probe for AFZ derivatization in the microenvironment of a silica plate. A design of experiments (DoE) approach was implemented using a Plackett–Burman design for risk assessment and a minimum run resolution IV design for response surface analysis. HPTLC–MS was used for the characterization of the fluorodensitometric probe generated by microwave-aided microlevel condensation of organic liquids and AFZ. The method demonstrated linearity in the range of 10–50 pg/band with high sensitivity (LOD: 3.0 pg/band, LOQ: 10.0 pg/band). Precision and accuracy were within acceptable limits. The method was successfully applied to pharmaceutical formulations and different plasma samples. The proposed method offers a sensitive, selective, and environmentally friendly approach for AFZ estimation at picoscale levels, adhering to white analytical chemistry principles and the QbD approach. |
| Sponsor | The director of Maliba Pharmacy College is obliged by the writers ofthis piece to supply the resources that allowed them to conduct theirresearch. Uka Tarsadia University's Provost and CEO, who provided thenecessary infrastructure and resources, also deserves gratitude fromthe writers of the manuscript. The authors extend their appreciation tothe Ongoing Research Funding Program (ORF-2025-726), King SaudUniversity, Riyadh, Saudi Arabia. |
| Language | en |
| Publisher | John Wiley and Sons Ltd |
| Subject | alfuzosin microenvironment microwave-assisted fluorodensitometric probe minimum run resolution IV design quality by design approach |
| Type | Article |
| Issue Number | 12 |
| Volume Number | 40 |
| ESSN | 1522-7243 |